Omega-speaker-systems iLD Series Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Monitore Omega-speaker-systems iLD Series herunter. Omega Speaker Systems iLD Series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 49
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Users Guide
www.omega.com
iSeries info:
www.omega.com/specs/iseries
®
Shop on line at
USA
MADE IN
iLD Big Display
Monitor/Controller
Embedded Ethernet
Seitenansicht 0
1 2 3 4 5 6 ... 48 49

Inhaltsverzeichnis

Seite 1 - User’s Guide

User’s Guidewww.omega.come-mail: [email protected] info:www.omega.com/specs/iseries™®Shop on line atUSAMADE INiLD Big DisplayMonitor/ControllerEmb

Seite 2 - Servicing Europe:

62.4 Serial Communication Interfaces (For Models with RS485 Port)The iLD Big Display controller/monitor with the Embedded Ethernet Server option board

Seite 3

72.4.1 Wiring RS485 InterfaceRS485 interface uses a two-wire communication system (one for transmitting and one forreceiving) plus a common wire to co

Seite 4

82.5 Network Communication Interfaces2.5.1 10Base-T RJ-45 PinoutThe 10BASE-T Ethernet network (RJ-45) system is used in the iServer for networkconnect

Seite 5

9PART 3NETWORK CONFIGURATION3.1 Network ProtocolsThe iServer can be connected to the network using standard TCP/IP protocols. It alsosupports ARP, H

Seite 6

3.3 DHCPDHCP, Dynamic Host Configuration Protocol enables individual computers or devices toextract their IP configurations from a server (DHCP server

Seite 7 - + - N/C

3.5 IP AddressEvery active device connected to the TCP/IP network must have a unique IP address.This IP address is used to build a connection to the i

Seite 8 - OUTPUT2 OUTPUT1

PART 4OPERATIONSAn industrial device with serial interfaces (PLC, CNC controllers, PC, Data DisplayDevices, etc.) can be connected to the serial port

Seite 9

Where:"*" is the selected Recognition Character. You may select any ASCII table symbol from"!" (HEX address "21") to the

Seite 10

4.4 OPERATIONSThis iServer can be used and configured in several ways, depending on user’spreference and network setup. It can be used in Telnet simul

Seite 11

154.5 Setup and Operation Using a Web Browser (continued)Figure 4.2 Device TypeFigure 4.3 iServer Home Page MenuIn order to access certain menu ite

Seite 12

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its pr

Seite 13

4.5.1 Read Devices• Read variables from up to eight different devices.• Read up to eight variables from the same device. • Read and write the setpoint

Seite 14

174.5.3 Device Setup• Device Setup helps you to see eight different variables or devices by “Check” box.• Up to four different devices or parameters c

Seite 15

184.5.4 Configuration• This section explains the Configuration page of the iServers’s Web interface.• When connecting your device to the iServer, the

Seite 16

4.5.4.A Serial Communication (continued)Transceiver: Can either be set to RS-232 or two-wire RS-485 (default is RS-485.)Modbus/TCP: A widely used prot

Seite 17

4.5.4.B Terminal Server (continued)Connection Control:Some serial devices accept connections or disconnectconnections based on certain signal conditi

Seite 18

214.5.5 Access ControlThis section describes the "Access Control" page of the iServers’s Web interface. Thispage allows the users to set u

Seite 19 - ADMINISTRATOR

4.5.5 Access Control (continued)Host Name: Refer to Section 3.4, DNS.MAC Address: This is also called Hardware address or Ethernet address, which is

Seite 20 - 092.4 Deg. C

4.6 Setting a New IP Address over the NetworkThe iServer is shipped with a default IP address of 192.168.1.200 and Subnet Mask of255.255.255.0. You

Seite 21 - MODIFY DEVICE PARAMETERS

244.7 Terminal Server FunctionIt is used to provide dedicated connectivity between computers and serial devicesthrough the iServer over the Ethernet,

Seite 22 - CONFIGURATION

4.8 Terminal EmulationOn this page you can send and receive data to and from the instrument. Simply, type thecommand in the open window and as you ty

Seite 23

TABLE OF CONTENTSPart 1: Introduction1.1 Safety and EMC Considerations...21.2 Des

Seite 24

264.9 Telnet SetupTelnet stands for Telecommunications Network, is a protocol that provides a way for users (orclients) to connect to computers (or s

Seite 25 - ACCESS CONTROL

4.9 Telnet Setup (continued)In the Configuration mode you can make any changes just like you would do using the WebBrowser. After connected to the i

Seite 26

284.10 HTTPGET ProgramYou can setup and read the information from the iServer by using the HTTPGETprogram. The following program can be used to read

Seite 27

4.11 ARP ProtocolARP is the Internet layer protocol responsible for determining the MAC (hardware)address that corresponds to a particular IP address

Seite 28

4.12 Remote Access (Tunneling)To "tunnel", in this context, is to transmit data between two points through a privateconduit on a shared or

Seite 29 - TERMINAL EMULATION

4.12.1 Remote iServer It’s recommended to configure the Remote iServer and have it up and running before theLocal iServer is configured.1. A static I

Seite 30

4.12.2 Local iServer 1. An IP address should be assigned to the iServer dynamically or statically (recommended).2. Use a browser to access the Local

Seite 31 - 4.9 Telnet Setup (continued)

334.13 Mail Notifier SoftwareThe Mail Notifier Software can be used only with NEWPORT Electronics instruments.For complete information of how to use

Seite 32

4.13.2 Program Options Setup and ConfigurationComplete program setup requires: • Entering a recipient for the email• Specifying connection details to

Seite 33

4.12.3 Device Setting and ConfigurationDevice setup requires:• Entering the IP address for iServer device (for example 192.168.1.200).• Specifying So

Seite 34

LIST OF FIGURES:Figure 1.1 iServer on the Ethernet Network...3Figure 2.1 Rear Panel View

Seite 35

PART 5SPECIFICATIONSSERIAL INTERFACE Interface: RS-422 or RS-485 (2 wire)Data Rates: 300 to 115200 bpsCharacters: 7 or 8 data bitsParity: odd, even, o

Seite 36

PART 6FACTORY PRESET VALUESPRESET PARAMETERS FACTORY DEFAULTSNetwork Interface:IP Address 192.168.1.200Gateway Address 0.0.0.0Subnet Mask 255.255.255.

Seite 37

APPENDIX A GLOSSARYUser of this manual should be familiar with following definitions:ARP (Address Resolution Protocol) is a protocol for mapping an In

Seite 38

39Appendix B IP AddressAn IP address is a unique 32-bit address assigned to a computer and includes:• A network ID number identifying a network.• A ho

Seite 39

Appendix C IP NetmaskIP Netmask or Subnet Mask is a 32-bit pattern of ones and zeros used to determinenetwork portion of an IP address from the host p

Seite 40 - ±10%, 50/60 Hz

Appendix D ASCII ChartASCII Dec Hex Binary ASCII Dec Hex BinaryChar No Parity Char No parityNUL 00 00 00000000 @ 64 40 01000000SOH 01 01 00000001 A 65

Seite 41

Appendix D ASCII Chart Continuation/ 47 2F 00101111 o 111 6F 011011110 48 30 00110000p112 70 011100001 49 31 00110001q113 71 011100012 50 32 00110010

Seite 42

43PART 7APPROVALS INFORMATION7.1 CE APPROVALS INFORMATIONThis product conforms to the EMC directive 89/336/EEC amended by93/68/EEC, and with the Euro

Seite 43

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) yearfrom the

Seite 44

M2542/0606Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop on line at omega.comTEMPERATUREThermocouple, R

Seite 45

NOTES, WARNINGS and CAUTIONSInformation that is especially important to note is identified by following labels:• NOTE • WARNING or CAUTION• IMPORTANT•

Seite 46

PART 1INTRODUCTION1.1 Safety and EMC ConsiderationsThis device is marked with the international caution symbol. It is important toread this manual bef

Seite 47

1.2 DescriptionThis iServer board can be purchased as a stand alone unit, or as an optionfor an iLD monitor/controller (Embedded Ethernet iServer) wit

Seite 48 - , omega.com

4PART 2HARDWARE2.1 Physical Characteristics and MountingFor physical dimensions and installation instructions see the Quickstart Manual.2.2 Rear Panel

Seite 49 - OMEGA…Of Course!

52.3 DIP Switches on the iServerFor Dipswitch access you must remove the main board from the case. Refer to theDisassembly Instructions in your iLD Bi

Kommentare zu diesen Handbüchern

Keine Kommentare